Ricerca:
.
TEKTRONIX
.
TTi Thurlby Thandar
.
Goodwill GW Instek
.
Weinschel Associates
.
Electro-Metrics
.
Solar Electronics
Antennas
Application Information
Capacitors
Coupling Networks
Essential Appartus Charts
Instruments
Line Impedence Networks
Probes
Pulse Trasformers
Resistive Devices
Trasformers
Wave Filters
Solar Electronics
>
Application Information
Type 6693-3L/3R-DC
Isolator Network |
Euro 0,00
Quantità
The Type 6693-3L/3R RF-DC Isolator Network consists of two units used as "buffer" networks in performing insertion loss tests on EMI filters while power current is flowing through the filter. The networks provide a high impedance in series with the power source
so that r.f. signals will not be deteriorated by the low impedance of the power source.
Disponibilità:
TYPE 7021-1
Phase Shift Network |
Euro 0,00
Quantità
The Type 7021-1 Phase Shift Network phases out the power frequency without disturbing the injected frequency seen by the VTVM, analog voltmeter, or scope
in Method CS01 of MIL-STD-462. The network prevents the power frequency from reaching the indicating device, but doesn't interfere with the normal power connection to the test sample. Properly adjusted, it has no effect
on the injected frequency, so the voltmeter or scope will indicate the injected level. Contains variable resistance and capacitance in a bridge-type circuit which is manually adjusted for null before the injected signal is applied. Does a fine job on 50 Hz, 60 Hz, and 400 Hz power lines. Either 115 volt or 230 volt operation.
Disponibilità:
TYPE 7429-1
1 Loop Antenna
Euro 0,00
Quantità
Disponibilità:
TYPE 9130-
1 Loop Antenna
Euro 0,00
Quantità
This antenna was designed as a replacement for Eaton 94608-1. It is similar to Stoddart 91117-2, 30-inch diameter loop, supplied with AN/URM-6B and NM-10A
EMI receivers. In addition to operating as a receiving antenna, the Type 9130-1 Loop Antenna is capable of carrying ten amperes in test setups for generating magnetic fields.
Disponibilità:
TYPE 9229-1 and 9230
1 Loop Antennas
Euro 0,00
Quantità
DESCRIPTION
This antenna was designed as a replacement for Eaton 94608-1. It is similar to Stoddart 91117-2, 30-inch diameter loop, supplied with AN/URM-6B and NM-10A
EMI receivers. In addition to operating as a receiving antenna, the Type 9130-1 Loop Antenna is capable of carrying ten amperes in test setups for generating magnetic fields.
Disponibilità:
Type 7115-1 OR
High Voltage Spark Tests Using
Euro 0,00
Quantità
The Type 7115-1 Transient Pulse Transformer is designed to be plugged into the SERIES output terminals of the Model 6254-5S Transient Generator to step up the transient or "spike" voltage. The Type 7115-2 Transient Pulse Transformer is designed to be plugged into the SERIES terminals of the Model 8282-1 Spike Generator. When specifications require a static discharge to the shield or case of the equipment under test, the Type 7510-1 Spark Gap can be useful.
Disponibilità:
7115-2
High Voltage Transient Pulse Tramsformer and Type 7510-1 SPARK GAP
Euro 0,00
Quantità
Using Type 7115-1 or 7115-2
High Voltage Transient Pulse Transformer and Type 7510-1 Spark Gap
The Type 7115-1 Transient Pulse Transformer is designed to be plugged into the SERIES output terminals of the Model 6254-5S Transient Generator to step up the transient or "spike" voltage. The Type 7115-2 Transient Pulse Transformer is designed to be plugged into the SERIES terminals of the Model 8282-1 Spike Generator. When specifications require a static discharge to the shield or case of the equipment under test, the Type 7510-1 Spark Gap can be useful.
Disponibilità:
TYPE 7415-3
R.F. Coupler and High Pass Filter
Euro 0,00
Quantità
There are those who disagree with the r.f. conducted susceptibility test setup of Method CS02 of MIL-STD-462. Homemade rigs have sprouted to comply with the coupling capacitor requirement, each with it own disadvantage. Our little Type 7415-3 R.F. Coupler is the answer. A neat little box with BNC connectors and a pair of binding posts, it is rated at 270 V.A.C. at the LINE terminals and 20 volts PMS into the GEN port.
Disponibilità:
Cable Induced Transients for Space Shuttle Program
Euro 0,00
Quantità
The design requirements for electrical equipment on board the Space Shuttle vehicle include cable induced currents, called "indirect lightning effects" as described in Rockwell International Specification MF0004 002. A system for providing "component number one" described
in Figure 15(b) of that specification
has been developed and includes three items as follows:
Disponibilità:
Type 6220-1A
Transformer for the Measurement of Low Frequency EMI Currents
Euro 0,00
Quantità
Disponibilità:
Calibration of Loop Antennas
Euro 0,00
Quantità
Calibration of Loop Antennas
Disponibilità:
EMI Prediction Graph
Euro 0,00